Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Clin Implant Dent Relat Res ; 25(6): 1187-1196, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37608501

RESUMEN

INTRODUCTION: Hypohidrotic ectodermal dysplasia (HED) patients suffering of oligo-anodontia require early dental treatment to improve oral functions and reduce social impairment. The aim of this study was to evaluate the skeletal growth, implant and prosthetic survival rate, success, and complications after the rehabilitation with a maxillary denture and an implant-supported overdenture provided by a sliding bar in case of severe hypodontia/anodontia related to HED. MATERIALS AND METHODS: This retrospective cohort study began in 2009. Nine patients over 7 years old with HED and associated oligo-anodontia who presented at the University of Bologna for dental treatment were included in the study. They were first treated with conventional dentures and then with a maxillary denture and an implant-supported overdenture with a sliding bar connected to two implants placed in the anterior mandible. The subjects treated were followed for 3-12 years. In each case, orthopanoramic and lateral cephalometric radiographic exam were taken before implant placement and annually after prosthetic load. Vertical and transverse dimensions of the mandible in the symphysis area at implant sites were taken on the lateral cephalometric radiography at the time of implant placement and after 5 years from the prosthetic loading to assess the presence or absence of an anterior mandibular growth. Biologic and mechanical complications were also recorded at every visit. RESULTS: A mandibular vertical growth under the implant apex, at the implant neck, and a sagittal growth of the symphysis after 5 years from the prosthetic loading were observed and measured. Implant and prosthetic success and survival rates were 100% after 8.1 years (mean) follow-up period. No complications were reported except in one patient, where the repositioning of a retentive cap on the counter bar in the superstructure was necessary after 3 years from the prosthetic loading. CONCLUSIONS: The present study suggests that the growth of the mandible near implant sites continues even after their positioning. Implants can be successfully placed and provide support for prosthetic rehabilitation in preteens patients with HED.


Asunto(s)
Anodoncia , Implantes Dentales , Displasia Ectodérmica , Humanos , Niño , Estudios de Cohortes , Prótesis de Recubrimiento , Estudios Retrospectivos , Anodoncia/complicaciones , Anodoncia/rehabilitación , Displasia Ectodérmica/complicaciones , Displasia Ectodérmica/cirugía , Mandíbula , Prótesis Dental de Soporte Implantado/efectos adversos , Resultado del Tratamiento , Retención de Dentadura
2.
Int J Biomater ; 2023: 2745262, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37457392

RESUMEN

This investigation aimed to compare the effectiveness of the OT Equator® (Rhein, Bologna, Italy) and the Locator attachment systems used to retain early loaded implant-retained overdentures. This study was designed as a multicenter randomised controlled trial of parallel groups. After implant placement, the patients were randomised to receive OT Equator® attachments in the test group or Locator attachments in the control group. The outcome measures were implant and prosthetic success and survival rates, any biological and technical complication, marginal bone loss, patients' satisfaction, and periodontal parameters. Overall, 42 patients were consecutively enrolled and treated. One implant was lost in the control group, while no implants were lost in the test group. No prostheses failed in both groups. Only a few complications were experienced in both groups. The main was represented by loss of retention of the attachments (retentive caps). The OT Equator® attachment showed statistically lower periodontal parameters. In conclusion, both attachment systems were suitable for overdenture implant retention.

3.
Radiol Case Rep ; 17(7): 2367-2369, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35570881

RESUMEN

Accessory spleen rupture can induce acute abdominal bleeding following minimal trauma or by atraumatic mechanisms. Spleen rupture is more frequent in pediatric patients and those affected by hematological diseases. We described the case of a 59-year-old male patient affected by hereditary spherocytosis referred to the emergency department for abdominal left side pain. An early ultrasound performed in the emergency department allowed to diagnosed hemoperitoneum by spontaneous bleeding of hypertrophic accessory spleen. Although abdomen computed tomography is the diagnostic method of choice, ultrasound can early detect sign of emoperitoneum in the emergency setting in case of hemodinamically unstable patient.

4.
Materials (Basel) ; 14(20)2021 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-34683790

RESUMEN

The objective of this study was to examine the effect of different conditions of simulated hydrostatic pulpal pressure on the µTBS of HEMA-based and HEMA-free dentin bonding agents (DBAs). The influence of dentin location (deep and superficial) on µTBS was also evaluated. Flat coronal dentin surfaces of extracted human molars were prepared. Three groups of resin-bonded specimens were exposed to different pulpal pressures. Pulpal pressure was maintained for 20 min for each group. A flowable resin composite was used for coronal build-up. The bonded teeth were sectioned and, after 24 h of water storage, stressed to failure using the microtensile tester (µTBS). Failed samples were analyzed by SEM inspection. HEMA-based DBAs were much more sensitive to pulpal pressure conditions than non-HEMA-containing DBAs. Pulpal pressure had a greater influence in deep dentin. The HEMA-free DBA was insensitive to the presence or absence of pulpal pressure condition. SEM inspection confirmed a relationship between the presence of voids inside the HEMA-based DBAs layer and the lower µTBS results. HEMA-based DBAs are more sensitive to pulpal pressure conditions than HEMA-free DBAs. Interestingly, HEMA-free DBA showed a greater number of water droplets at resin-dentin interface in all tested conditions.

5.
J Ultrasound ; 24(2): 115-123, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33851369

RESUMEN

A first screening by ultrasound can be relevant to set a specific diagnostic and therapeutic route for a patient with a COVID-19 infection. The finding of bilateral B-lines and white lung areas with patchy peripheral distribution and sparing areas is the most suggestive ultrasound picture of COVID-19 pneumonia. Failure to detect bilateral interstitial syndrome (A pattern) on ultrasound excludes COVID-19 pneumonia with good diagnostic accuracy, but does not exclude current infection. The use of shared semiotic and reporting schemes allows the comparison and monitoring of the COVID-19 pulmonary involvement over time. This review aims to summarise the main data on pulmonary ultrasound and COVID-19 to provide accurate and relevant information for clinical practice.


Asunto(s)
COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Ultrasonografía/métodos , Humanos , Reproducibilidad de los Resultados , SARS-CoV-2 , Sensibilidad y Especificidad , Ultrasonografía/tendencias
6.
Eur J Dent ; 15(2): 290-294, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33622005

RESUMEN

OBJECTIVE: Preliminary data on survival and success rates of immediately loaded, maxillary, screw-retained, implant-supported, fixed restorations delivered on narrow and low-profile OT Equator abutments (OT Bridge, Rhein'83) were evaluated. MATERIALS AND METHODS: This retrospective study evaluated data collected from patients rehabilitated with OT Bridge prosthetic concept between November 2017 and February 2019 in six different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. RESULTS: A total of 76 implants were inserted in 14 patients. Patients were followed for a mean period of 15.8 months (range = 12-24). All the patients receive OT Equator (Rhein'83) as intermediate abutments. One year after loading, one implant failed (1.3%). None of the prosthesis failed. One prosthetic complication was experienced in one patient. Three out of 76 implants were connected to the prosthetic framework using only the Seeger system, without screw. Difference in OHIP values was statistically significant (71.9 ± 8.5; p = 0.000). One year after loading, MBL was 0.21 ± 0.11 mm and p-value was 0.000. One year after loading, 8.7% of the examined implant sites present positive bleeding on probing, while 6.4% of the implant sites presented plaque. CONCLUSION: The OT Equator abutments (Rhein'83) showed successful results when used to support maxillary fixed dental prosthesis delivered on four to six implants. High implant and prosthetic survival rates, very low complications, high patient satisfaction, and good biological parameters, including only 0.2 mm of bone remodeling were experienced one year after function. Further studies are needed to confirm these preliminary results.

7.
J Ultrasound ; 23(2): 217-221, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32297175

RESUMEN

Thoracic ultrasound seems to adapt to the screening for lung involvement of patients with suspected or ascertained SARS-COVID-19 infection due to its characteristics of easy applicability. It can be also a relevant method in monitoring patients. B lines are early finding of COVID-19, even in mild-symptomatic subjects; in the most serious cases such as pre-ARDS or ARDS, the B lines end up filling the ultrasound image almost completely, until it merges, so as to create a single hyperechoic image named as "white lung", with distortion and irregularity of the pleural line. In advanced stage, lung consolidations are present, representing pulmonary pathological areas that are no longer normally ventilated.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , Tórax/diagnóstico por imagen , Ultrasonografía , COVID-19 , Humanos , Pandemias , SARS-CoV-2
8.
Dent J (Basel) ; 6(4)2018 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-30544970

RESUMEN

PURPOSE: To analyze implant and prosthetic survival rates, complications, patient satisfaction, and biological parameters of patients rehabilitated with implant overdentures (IOV) on splinted and nonsplinted implants and different attachment systems, in function for one to 17 years. METHODS: This retrospective study evaluated data collected from patients rehabilitated with implant overdentures between January 2001 and December 2016 in nine different centers. Outcome measures were implant and prosthetic success rates, mechanical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. RESULTS: A total of 581 implants were installed in 194 patients. Patients were followed for a mean period of 60.6 months (range 6⁻206). Eighty-nine patients received 296 low profile attachment (OT Equator), 62 patients received 124 ball attachments, and 43 patients received 107 Locator attachments. In eighty-three patients the implants were splinted with computer aided design/computer aided manufacturing (CAD/CAM) or casted bar. At the last follow-up, 10 implants failed in eight patients. Statistical significance was found for failed prostheses (P = 0.0723) and complications (P = 0.0165), with better values for splinted implants. No statistically significant differences were found in proportion of implant and prosthetic failure (P > 0.05). At a five-year follow-up, proportion of complications (P = 0.0289) and failed prostheses (P = 0.0069) were statistically higher for IOV on Locator attachments. No difference was founded in MBL at one- and two-year follow-up between different attachment systems (P > 0.05). Statistically significant improvement in all the OHIP categories was reported in all the patients, after one year of function. CONCLUSIONS: Implant overdenture showed high implant and prosthetic survival rates, low complications, high patient satisfaction, and good biological parameters in the long-term follow-up. Splinting the implants may reduce number of mechanical complications. Locator attachments showed higher number of complications. Further studies are needed to confirm these preliminary results.

9.
Comput Intell Neurosci ; 2018: 9616301, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30344600

RESUMEN

It is well known that the evaluation of a product from the shelf considers the simultaneous cerebral and emotional evaluation of the different qualities of the product such as its colour, the eventual images shown, and the envelope's texture (hereafter all included in the term "product experience"). However, the measurement of cerebral and emotional reactions during the interaction with food products has not been investigated in depth in specialized literature. The aim of this paper was to investigate such reactions by the EEG and the autonomic activities, as elicited by the cross-sensory interaction (sight and touch) across several different products. In addition, we investigated whether (i) the brand (Major Brand or Private Label), (ii) the familiarity (Foreign or Local Brand), and (iii) the hedonic value of products (Comfort Food or Daily Food) influenced the reaction of a group of volunteers during their interaction with the products. Results showed statistically significantly higher tendency of cerebral approach (as indexed by EEG frontal alpha asymmetry) in response to comfort food during the visual exploration and the visual and tactile exploration phases. Furthermore, for the same index, a higher tendency of approach has been found toward foreign food products in comparison with local food products during the visual and tactile exploration phase. Finally, the same comparison performed on a different index (EEG frontal theta) showed higher mental effort during the interaction with foreign products during the visual exploration and the visual and tactile exploration phases. Results from the present study could deepen the knowledge on the neurophysiological response to food products characterized by different nature in terms of hedonic value familiarity; moreover, they could have implications for food marketers and finally lead to further study on how people make food choices through the interactions with their commercial envelope.


Asunto(s)
Encéfalo/fisiología , Comportamiento del Consumidor , Percepción del Tacto/fisiología , Percepción Visual/fisiología , Adulto , Electroencefalografía , Conducta Alimentaria/fisiología , Conducta Alimentaria/psicología , Femenino , Alimentos , Humanos , Masculino , Filosofía , Reconocimiento en Psicología/fisiología , Adulto Joven
10.
Clin Genitourin Cancer ; 13(1): 39-43, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24999168

RESUMEN

BACKGROUND: The aim of this study was to assess early serum prostate-specific antigen (PSA) changes in patients treated with abiraterone and to correlate those changes with clinical outcome. PATIENTS AND METHODS: We retrospectively evaluated 103 patients with castrate-resistant prostate cancer (CRPC) treated with compassionate use of abiraterone in Romagna, Italy. In these patients, serum PSA levels were monitored every 4 weeks, and a time course of serum PSA levels was obtained. The PSA flare phenomenon was evaluated. The log-rank test was applied to compare survival between groups of patients according to early PSA level changes. RESULTS: Of 103 patients, 43 (41.7%) had an immediate PSA response, whereas 9 (8.7%) had an initial PSA flare. Of the 9 patients with PSA flare, 5 attained a subsequent PSA response. The temporary PSA flare exceeded baseline values by a median of 19.7% (range, 5%-62.9%). The median PFS of the 9 patients in the PSA-flare group was higher compared with patients without the PSA flare (10.5 vs. 6.4 months; P = .0999) but was similar to the subgroup of patients with immediate PSA response (10.5 vs. 10.7 months; P = .7019). In the multivariate analysis, only the PSA response remained as a predictor of progression-free survival (PFS) (P < .0001) and overall survival (OS) (P = .0003), respectively. CONCLUSION: PSA flare occurs not infrequently in patients with CRPC who respond to abiraterone. Patients should be informed of this possible PSA flare phenomenon.


Asunto(s)
Androstenos/uso terapéutico , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata Resistentes a la Castración/sangre , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Anciano , Anciano de 80 o más Años , Supervivencia sin Enfermedad , Humanos , Italia , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Estudios Retrospectivos , Análisis de Supervivencia , Resultado del Tratamiento
11.
BMJ Case Rep ; 20132013 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-23576648

RESUMEN

The purpose of this study was to determine the potential of platelet-rich fibrin (PRF) membranes used for guided bone and tissue regeneration. A patient with insufficient alveolar ridge width in aesthetic zone was enrolled. The patient's blood was centrifuged to obtain PRF membranes. Autogenous bone graft was mixed with bovine hydroxyapatite, PRF particles and applied to fill the defect. Five PRF membranes were placed over the bone mix. After 4 months a cone-beam CT was performed to evaluate bone regeneration. The use of PRF as cover membrane permitted a rapid epithelisation and represented an effective barrier versus epithelial cell penetration. After 4 months the site appeared precociously healed and the bone volume increased. This new approach represents a predictable method of augmenting deficient alveolar ridges. Guided bone regeneration with PRF showed limitation compared with guided bone regeneration using collagen membrane in terms of bone gain. The association of collagen membrane and PRF could be a good association.


Asunto(s)
Aumento de la Cresta Alveolar/métodos , Plaquetas/química , Regeneración Ósea , Fibrina/uso terapéutico , Regeneración Tisular Guiada Periodontal/métodos , Implantación Dental Endoósea , Durapatita/uso terapéutico , Humanos
12.
Clin Lung Cancer ; 14(1): 28-33, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22537509

RESUMEN

BACKGROUND: Although small-cell lung cancer is a chemosensitive malignancy, most patients rapidly relapse. Results of second-line treatment are generally poor. We conducted a phase II study to evaluate the activity and toxicity of a combination of gemcitabine and paclitaxel as second-line chemotherapy. PATIENTS AND METHODS: Eligible patients were refractory or relapsed small-cell lung cancer, with an Eastern Cooperative Oncology Group performance status of 0-2 and measurable disease. Paclitaxel was administered at 135 mg/m(2) days 1 and 8 immediately followed by gemcitabine at 1000 mg/m(2) every 3 weeks up to 6 courses. Restaging of disease was scheduled every 3 courses. RESULTS: Forty-one patients were enrolled. The median age was 65 years. Nineteen patients were considered refractory (progressive disease during or within 90 days from completion of first-line treatment), whereas 22 patients were chemotherapy sensitive. A total of 135 courses was administered (range, 1-6; median, 3). Nine patients achieved a partial remission (partial response, 22%), and 10 patients had stable disease (24%), with a disease control rate (partial response + stable disease) of 46%: in 12 (55%) of 22 patients who were sensitive and in 7 (37%) of 19 patients with refractory disease, respectively. All partial responses but one were observed in the sensitive group. The median duration of response was 5 months. The most-frequent severe toxicities were neutropenia grade 3-4 and neurologic grade 3 in 24% and 7% of delivered courses, respectively. CONCLUSIONS: The combination of gemcitabine and paclitaxel investigated in our study achieved a high disease control rate, but the schedule we adopted appeared to be quite toxic.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Pulmonares/tratamiento farmacológico , Recurrencia Local de Neoplasia/tratamiento farmacológico , Carcinoma Pulmonar de Células Pequeñas/tratamiento farmacológico , Adulto , Anciano , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Desoxicitidina/administración & dosificación , Desoxicitidina/análogos & derivados , Supervivencia sin Enfermedad , Resistencia a Antineoplásicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso/inducido químicamente , Neutropenia/inducido químicamente , Paclitaxel/administración & dosificación , Gemcitabina
13.
BMJ Case Rep ; 20122012 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-22729329

RESUMEN

The aim of this study was to describe the clinical treatment of young patients, affected by ectodermal dysplasia (ED), and to possibly establish clinical guidelines. The study design was case series. ED syndromes (EDs) are a heterogeneous group of inherited diseases characterised by abnormal development of tissues of ectodermal origin. The most common form of EDs is X linked hypohidrotic ED (HED). Characteristic triad of HED is oligo-anodontia, hypotricosis, hypo-anhydrosis. Oligo-anodontia is one of the most severe impairment, since it affects chewing, swallowing, speech, esthetics and social relation. Early prosthetic rehabilitation (at 2-3 years of age), with partial or complete dentures, is essential to improve oral function and reduce the social impairment.


Asunto(s)
Displasia Ectodermal Anhidrótica Tipo 1/rehabilitación , Estética Dental , Masticación , Niño , Preescolar , Dentadura Completa , Dentadura Parcial , Displasia Ectodermal Anhidrótica Tipo 1/fisiopatología , Humanos , Masculino , Habla
14.
Tumori ; 98(6): 696-701, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23389354

RESUMEN

AIMS AND BACKGROUND: Non-pegylated liposomal doxorubicin (NPLD) (Myocet) has shown marked in vitro activity in castration-resistant prostate cancer (CRPC) and also in docetaxel-resistant cells, higher than that shown by pegylated liposomal doxorubicin. Its activity would seem to be due to a high intracellular drug concentration and induction of Golgi-dependent apoptosis. On the basis of these results, a clinical study was designed to assess the activity of NPLD and low-dose prednisone in second-line therapy. METHODS: Fifty-four patients were enrolled and evaluated. Eligibility criteria were histologically confirmed CRPC, PSA >20 ng/mL or measurable lesions according to the RECIST criteria, previous docetaxel-based chemotherapy, and adequate cardiac function. Patients were treated with weekly intravenous NPLD 25 mg/m2 and daily prednisone 10 mg until progression. RESULTS: Median patient age was 69 years (range, 52-83) and median baseline PSA concentration was 120 ng/mL (range, 5.35-4350). Sixteen (29.6%) patients had measurable lesions. Objective or PSA responses (>50% reduction) were observed in 8 (14.8%) patients. The median time to progression was 2.8 months and the median overall survival was 11.3 months. Toxicity was generally mild (grade 1-2) and infrequent, with grade 3-4 neutropenia in 12.9% of cases. Grade 3 nonhematological toxicities included nausea in 2 patients (3.7%) and fatigue and stomatitis in 1 case (1.9%). No drug-related serious adverse events were reported. CONCLUSIONS: Weekly administration of NPLD is a well tolerated treatment with proven albeit limited activity.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Biomarcadores de Tumor/sangre , Carcinoma/tratamiento farmacológico , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/tratamiento farmacológico , Testosterona/sangre , Anciano , Anciano de 80 o más Años , Antibióticos Antineoplásicos/administración & dosificación , Antibióticos Antineoplásicos/efectos adversos , Antineoplásicos Hormonales/administración & dosificación , Antineoplásicos Hormonales/efectos adversos , Carcinoma/sangre , Carcinoma/secundario , Doxorrubicina/administración & dosificación , Doxorrubicina/efectos adversos , Esquema de Medicación , Humanos , Liposomas , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Orquiectomía , Prednisona/administración & dosificación , Prednisona/efectos adversos , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/patología , Resultado del Tratamiento
15.
Med. oral patol. oral cir. bucal (Internet) ; 16(3): 411-417, mayo 2011. ilus, tab
Artículo en Inglés | IBECS | ID: ibc-93023

RESUMEN

Objective: The purpose of the study was to evaluate the effect of water storage, adhesive system and root canalregion on the hydrolytic degradation of dentin bonds to carbon fiber posts.Study design: Fiber posts were bonded to the root canals using different adhesive systems and composites: SB1XT group (Scotchbond 1 XT/RelyX ARC), OBF group (One Up Bond F Plus/Ionotite F), and AB2 group (All Bond2/C&B) After water storage (10 days), all roots were sectioned into 1 mm beams and divided into coronal or apicalgroup. The specimens were stored in water at 22-26 °C temperature for 15 or 60 days and tested for microtensilebond strength at a crosshead speed of 0.9 mm/min after the calculation of the bonding area. Statistical analysis wasperformed with ANOVA followed by Tukey test to detect differences between groups (α=0.05). SEM investigationwas performed to determine the mode of fracture.Results: Bond strength at coronal and apical half showed significant differences between experimental groupsboth after 15 and 60 days of water storage. Premature failures were observed in 16-20% of specimens beforestorage in water.Conclusions: For the bonding systems tested, clinicians should consider that bond strength inside the root canal atapical half is lower than at coronal half irrespective of the adhesive system. The adhesion within the root canal ispossible for SB1 XT and OBF groups unlike the AB2 group where adhesion to root canal dentine is not reliable.Nevertheless, apical half represents the worst scenario in which is possible to obtain a durable adhesion (AU)


No disponible


Asunto(s)
Humanos , Recubrimientos Dentinarios/análisis , Preparación del Conducto Radicular/métodos , Raíz del Diente/cirugía , Adhesividad , Cementos Dentales/farmacocinética
16.
J Cell Physiol ; 226(11): 3035-42, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21302303

RESUMEN

The efficacy of therapy for hormone-refractory prostate cancer (HRPC) is still unsatisfactory and new agents and therapeutic modalities are needed. The aims of the present work were to examine the in vitro activity and mechanisms of action of doxorubicin (DX), pegylated liposomal DX (PLDX), and non-pegylated liposomal DX (NPLDX) in DU145 and taxane-resistant DU145-R HRPC cell lines. Drug activity and incorporation, apoptosis, and expression of cell death-related markers were evaluated by SRB test, cytofluorimetric assays, and Western blot, respectively. Among the different DX formulations, NPLDX showed the highest cytotoxic activity in both cell lines, with more than 50% of apoptotic cells at only 1/10 of the plasma peak concentration after 72 h exposure. Anthracyclines, in particular NPLDX, were highly concentrated in the Golgi apparatus. Moreover, a significant increase was observed in the expression of CD95 receptor, GD3 ganglioside and, caspase-2 and -8 active forms in both cell lines followed by caspase-3 activation and mitochondrial membrane depolarization. The Golgi apparatus, probably acting as a stress sensor, intensified the conventional apoptotic mechanism induced by anthracyclines. Our data support the hypothesis that organelle-dependent initiation of cell death other than that induced by mitochondria and nucleus is a research area worthy of pursuing and suggest that the Golgi apparatus could be an ideal target for anti-cancer therapy. Of note, the activity of NLPDX in taxane-resistant DU145-R cells warrants further evaluation as second-line treatment of advanced HRPC after taxane failure.


Asunto(s)
Antraciclinas/farmacología , Antineoplásicos/farmacología , Aparato de Golgi/efectos de los fármacos , Neoplasias de la Próstata/metabolismo , Antraciclinas/metabolismo , Antineoplásicos/metabolismo , Apoptosis/efectos de los fármacos , Hidrocarburos Aromáticos con Puentes/farmacología , Caspasas/biosíntesis , Línea Celular Tumoral , Activación Enzimática , Gangliósidos/biosíntesis , Humanos , Masculino , Potencial de la Membrana Mitocondrial/efectos de los fármacos , Taxoides/farmacología , Receptor fas/biosíntesis
17.
Med Oral Patol Oral Cir Bucal ; 16(3): e411-7, 2011 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20526268

RESUMEN

OBJECTIVE: The purpose of the study was to evaluate the effect of water storage, adhesive system and root canal region on the hydrolytic degradation of dentin bonds to carbon fiber posts. STUDY DESIGN: Fiber posts were bonded to the root canals using different adhesive systems and composites: SB1 XT group (Scotchbond 1 XT/RelyX ARC), OBF group (One Up Bond F Plus/Ionotite F), and AB2 group (All Bond 2/C&B) After water storage (10 days), all roots were sectioned into 1 mm beams and divided into coronal or apical group. The specimens were stored in water at 22-26 °C temperature for 15 or 60 days and tested for microtensile bond strength at a crosshead speed of 0.9 mm/min after the calculation of the bonding area. Statistical analysis was performed with ANOVA followed by Tukey test to detect differences between groups (α=0.05). SEM investigation was performed to determine the mode of fracture. RESULTS: Bond strength at coronal and apical half showed significant differences between experimental groups both after 15 and 60 days of water storage. Premature failures were observed in 16-20% of specimens before storage in water. CONCLUSIONS: For the bonding systems tested, clinicians should consider that bond strength inside the root canal at apical half is lower than at coronal half irrespective of the adhesive system. The adhesion within the root canal is possible for SB1 XT and OBF groups unlike the AB2 group where adhesion to root canal dentine is not reliable. Nevertheless, apical half represents the worst scenario in which is possible to obtain a durable adhesion.


Asunto(s)
Carbono , Recubrimiento Dental Adhesivo , Cementos Dentales , Materiales Dentales , Recubrimientos Dentinarios , Técnica de Perno Muñón , Fibra de Carbono , Análisis del Estrés Dental , Hidrólisis , Ensayo de Materiales , Tratamiento del Conducto Radicular , Factores de Tiempo
18.
Dent Mater ; 23(6): 705-13, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16904175

RESUMEN

OBJECTIVES: Dentin bonds made with one-bottle etch-and-rinse and self-etch adhesives are affected by the formation of interfacial blisters, porosities and deterioration. The first objective of this study was to evaluate the fluid flow through resin-dentin interfaces created by self-etching adhesives applied to deep dentin using a replica technique and by directly measuring dentin permeability (P). The second objective was to examine the effect of intrapulpal pressure on the microtensile bond strength of these adhesives. METHODS: A fluid-transport model was used to measure the fluid permeability (%P) through different adhesives. Impressions of bonded dentin were taken with a polyvinylsiloxane impression material to monitor fluid transudation from the surface of the adhesive. Positive replicas were fabricated for SEM examination. Two groups of resin-bonded specimens (pulpal pressure versus no pulpal pressure) were created for microtensile bond strength evaluation. Adhesive application was performed under 0 cm H(2)O. Pulpal pressure group was submitted to 20 cm H(2)O of pulpal pressure during build-up procedures. RESULTS: Clearfil Protect Bond exhibited the lowest permeability and fewest numbers of fluid droplets over the surface of the bonded dentin. G-Bond and Clearfil-S3 Bond were more permeable than Clearfil Protect Bond. One Up Bond F was the most permeable adhesive. A highly significant correlation was observed between the relative permeability of these adhesives (%P) and the number of fluid droplets on the adhesive surfaces. The application of pulpal pressure significantly reduced bond strength. SIGNIFICANCE: Resin-dentin bonds created by contemporary self-etch adhesives are susceptible to fluid permeation induced by pulpal pressure. HEMA-based adhesives showed the largest reductions in bond strengths after pulpal pressure application.


Asunto(s)
Recubrimiento Dental Adhesivo , Pulpa Dental/fisiología , Permeabilidad de la Dentina , Recubrimientos Dentinarios , Cementos de Resina , Grabado Ácido Dental/métodos , Adulto , Análisis de Varianza , Análisis del Estrés Dental , Humanos , Presión Hidrostática , Microscopía Electrónica de Rastreo , Diente Molar , Análisis de Regresión , Técnicas de Réplica , Resistencia a la Tracción , Humectabilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...